LYC High-Precision Oil Purifier is a mobile integrated filtration unit with graded filtration, removing solid contaminants from hydraulic oil. Ideal for new oil filling, bypass filtration, and used oil regeneration.
1. Product Overview
The LYC High-Precision Oil Purifier is a mobile integrated oil purification equipment specially designed for various hydraulic
systems. Engineered to address the critical need for maintaining hydraulic oil cleanliness, this purifier adopts a graded
filtration structure that quickly removes solid particles, metal wear debris, and dust contaminants from hydraulic
oil—effectively improving oil cleanliness and extending the service life of hydraulic components.
Key features of the LYC series include:
· Versatile application: Suitable for new oil filling, on-site bypass filtration, and used oil regeneration
· Compact and movable design: Ideal for daily maintenance in industrial workshops, construction sites, and power plants
· Easy operation: User-friendly controls requiring minimal training
· Cost-effective: Reduces oil replacement frequency and lowers overall maintenance costs
2. Product Performance
2.1 Hydraulic Oil Optimization
The LYC purifier is specifically optimized for hydraulic oil working conditions, adapting to conventional hydraulic oil
viscosity ranges without damaging original oil additives. The filtration process is purely physical—no chemical reactions
occur—ensuring that the oil's anti-wear, anti-oxidation, and anti-foam properties remain intact.
2.2 Graded High-Precision Filtration
Adopting a graded high-precision filtration structure, the LYC series effectively intercepts fine solid contaminants down to
the micron level. This multi-stage approach:
· Captures particles of varying sizes in different filtration layers
· Extends filter element service life by distributing contaminant load
· Stably controls oil pollution level to meet NAS or ISO cleanliness standards
· Protects hydraulic precision components (pumps, valves, actuators) from abrasive wear
2.3 Compact & Mobile Design
Equipped with universal moving casters and a compact structure, the LYC purifier is:
· Easy for one-person handling and positioning
· Flexible for on-site oil filtering and replacement across multiple equipment locations
· Space-saving for workshops with limited floor area
2.4 Safe & Reliable Operation
The purifier features built-in overload and overflow dual safety protection, ensuring:
· Stable operation even under fluctuating inlet conditions
· Low noise output, suitable for noise-sensitive environments
· Support for long-time continuous working without performance degradation
3. Technical Specifications
Parameter Specification
Series LYC High-Precision Oil Purifier
Application Hydraulic oil purification, new oil filling, bypass filtration, used oil regeneration
Filtration structure Graded (multi-stage) high-precision filtration
Pump type Industrial gear pump (strong self-priming, stable flow)
Frame material Anti-corrosion carbon steel with rust-proof coating
Pressure indication Differential pressure indicator (visual clogging status)
Safety protection Overload protection + overflow bypass valve (dual protection)
Power supply 380V industrial power (standard)
Motor Energy-efficient, supports frequent start-stop operation
Mobility Universal casters (one-person operation)
Noise level Low noise, suitable for continuous operation
Applicable media Hydraulic oil, and similar viscosity lubricating oils
4. Technical Conditions
4.1 High-Performance Oil Pump
The LYC series is equipped with an industrial gear pump featuring:
· Strong self-priming ability—no need for manual priming
· Stable flow output regardless of varying inlet conditions
· Sufficient capacity to meet large circulation filtration requirements for hydraulic stations
4.2 Durable Frame Construction
The frame is manufactured from anti-corrosion carbon steel with a rust-proof coating, making it suitable for:
· Complex indoor working environments (high humidity, chemical exposure)
· Outdoor working conditions (temperature variation, moisture)
· Long-term industrial use without structural degradation
4.3 Differential Pressure Monitoring
Fitted with a differential pressure indicator, the LYC purifier enables:
· Direct visual judgment of filter element clogging status
· Timely maintenance and replacement scheduling
· Prevention of bypass valve opening and unfiltered oil circulation
4.4 Standard Industrial Power Supply
The standard 380V industrial power supply configuration ensures:
· Wide compatibility with most industrial facility power systems
· Energy-efficient motor operation
· Reliable performance under frequent start-stop conditions
5. Scope of Application
The LYC High-Precision Oil Purifier is suitable for a wide range of applications across multiple industries:
5.1 Hydraulic Systems
· Hydraulic stations – Main and auxiliary hydraulic power units
· Hydraulic pump stations – Centralized hydraulic oil circuits
· Machine tool hydraulic systems – Grinders, milling machines, presses, and CNC equipment
· Construction machinery hydraulic circuits – Excavators, loaders, cranes, and bulldozers
5.2 Lubrication Systems
· Lubricating oil circuits requiring similar viscosity grades to hydraulic oil
· Circulating lubrication systems in gearboxes and compressors
· Turbine lubrication oil conditioning
5.3 Operational Scenarios
· New oil filling – Cleaning fresh oil before system introduction
· On-site bypass filtration – Continuous oil cleaning while equipment operates
· Used oil regeneration – Restoring oil quality for extended service life
5.4 Applicable Industries
· Metallurgy and steel production
· Automotive manufacturing
· Heavy machinery manufacturing
· Power generation and thermal plants
· Construction and mining
· Marine and offshore equipment
6. Operational Benefits
· Extended equipment life – Clean oil reduces wear on pumps, valves, and actuators
· Reduced downtime – Less frequent system failures and maintenance interruptions
· Lower oil consumption – Extended oil change intervals through regeneration
· Cost savings – Reduced filter replacement frequency and oil procurement costs
· Environmental compliance – Reduced hazardous waste oil generation
7. Maintenance Guidelines
1. Differential Pressure Monitoring – Check the differential pressure indicator regularly. Replace filter elements when
the indicator signals clogging (typically 2–3× initial clean pressure drop).
2. Element Replacement – Replace all filter elements in the graded filtration train simultaneously. Use only recommended
replacement elements to maintain performance.
3. Frame Cleaning – Wipe the frame and control panel with a clean, dry cloth. Avoid water ingress into electrical components.
4. Caster Inspection – Check casters for smooth movement. Clean any debris wrapped around wheel axles.
5. Hose Inspection – Inspect inlet/outlet hoses for cracks, abrasion, or leakage. Replace if damaged.
6. Periodic Oil Sampling – Periodically test outlet oil cleanliness to verify filtration performance and determine optimal
element replacement intervals.
8. FAQ (Frequently Asked Questions)
Q1: What types of hydraulic oil can the LYC purifier handle?
A: The LYC series is designed for conventional hydraulic oils (ISO VG 32, 46, 68, etc.). It is also suitable for lubricating oils
with similar viscosity grades. For synthetic or fire-resistant fluids, please consult our technical team for compatibility
verification.
Q2: What is the filtration precision of the LYC oil purifier?
A: The LYC series adopts graded filtration. The final stage can achieve precision down to 3–5μm (absolute), effectively
controlling oil cleanliness to NAS 1638 Class 6–8 depending on inlet condition and model selection.
Q3: Can the LYC purifier remove water from hydraulic oil?
A: The standard LYC configuration focuses on solid particle removal. For water removal (free and emulsified water),
we offer optional dehydration filter elements or recommend our LYC-J series coalescing dehydration units.
Q4: Is the purifier suitable for continuous 24-hour operation?
A: Yes. The LYC purifier is designed for long-time continuous operation with built-in overload and overflow dual safety
protection. Regular maintenance checks are recommended during extended operation.
Q5: How do I know when to replace the filter elements?
A: Monitor the differential pressure indicator on the control panel. When the needle reaches the red zone (typically 0.15–0.2
MPa above clean initial value), element replacement is required.
Q6: Can the LYC purifier be used while the hydraulic system is running?
A: Yes. The purifier supports bypass (offline) filtration—connect it to the hydraulic system's return or suction line while
equipment continues normal operation. This is the most common application mode.
Q7: What is the noise level during operation?
A: The LYC series is designed for low noise operation. Typical noise levels are below 75 dB(A) at 1 meter, making it suitable
for indoor workshop environments.
Q8: What maintenance is required for the LYC oil purifier?
A: Regular tasks include monitoring differential pressure, replacing filter elements when indicated, cleaning the frame
and casters, and inspecting hoses and electrical connections. No specialized maintenance is required.
Q9: Can the purifier handle high-viscosity oils?
A: The LYC series is optimized for conventional hydraulic oil viscosity (ISO VG 32–68). For higher viscosity oils, please consult
our technical team for pump and motor sizing adjustments.
Q10: Does the purifier damage oil additives during filtration?
A: No. The filtration process is purely physical—solid particles are captured by the filter media without affecting the chemical
structure of the oil. Additives remain intact.
Q11: What is the typical flow rate of the LYC purifier?
A: Flow rates vary by model. Standard LYC models range from 25 L/min to 100 L/min. Please refer to specific model datasheets
for exact ratings.
Q12: Are there explosion-proof versions available?
A: Yes. Explosion-proof versions with EX-rated motors and electrical components are available upon request for hazardous
environments (oil fields, chemical plants, etc.).
Q13: What spare parts should I keep in stock?
A: We recommend keeping a complete set of replacement filter elements and spare inlet/outlet hoses. Additional O-ring
seal kits are also recommended for longer-term inventory.
Q14: Do you offer custom configurations for non-standard applications?
A: Yes. We offer custom flow rates, filtration precision, power supply configurations, and material options. Please provide
your application requirements for a tailored solution.
Let me know if you need this translated back into Chinese, or if you would like to combine all products into a single
comprehensive catalog.
LYC High-Precision Oil Purifier – Mobile, Efficient Hydraulic Oil Cleaning Solution
Similar ProductsVIEW MORE >