1. Single Cleaning Duration (Discharging/Brushing Time)
Setting range: 1~99 seconds
Factory default: 10~30 seconds. For media with high dirt content or high viscosity, it can be adjusted to 40~60 seconds.
2. Timed Cleaning Interval (Cycle between two cleanings)
Setting range: 1 minute ~ 99 hours
Main electrical control parameters:
Minute level: 1~59 min
Hour level: 1~99 h
3. Supplementary Notes
This parameter range is universally applicable to brush-type, suction-type and scraper-type self-cleaning filters.
Differential pressure triggering is the priority logic, while timed setting serves as forced backup cleaning.
Customized models can support extended cycles, with a maximum of 7 days.
Previous article: What precautions should be taken for the installation and maintenance of return line filters?