Product
Electric heat trace leak proof gas drainer
Electric heat trace leak proof gas drainer
Electric heat trace leak proof gas drainer
Electric heat trace leak proof gas drainer
Electric heat trace leak proof gas drainer
Electric heat trace leak proof gas drainer

Electric heat trace leak proof gas drainer

The electric heat tracking anti-leakage gas drainer is composed of ordinary drainer and anti-leakage device, and the water seal height is used to overcome the gas pressure, so as to seal the gas. When the effective water level of the drainer is abnormally reduced due to the pressure fluctuation of the gas pipe network or other reasons, the gas breaks down the water seal, and the anti-leakage device acts to close the overflow port, curb the gas leakage and prevent accidents.

  • Material: Q325
  • Brand Name: Aite Environmental Protection

Product Introduction

Electric heat trace leak proof gas drainer is composed of ordinary drainer and anti-leakage device, and the water seal height is used to overcome the gas pressure, so as to seal the gas. When the effective water level of the drainer is abnormally reduced due to the pressure fluctuation of the gas pipe network or other reasons, the gas breaks down the water seal, and the anti-leakage device acts to close the overflow port, curb the gas leakage and prevent accidents.


Principle of Operation

Electric heat trace leak proof gas drainer mainly connects the anti-breakdown and non-leakage gas drainer into the gas conveying pipeline. The condensate water in the gas pipeline enters the high pressure chamber of the drainer through the drain pipe, and then enters the low pressure chamber of the drainer through the connected pipe of the high and low pressure chamber on the partition board to collect the condensate water and automatically discharge the condensate water in the gas pipeline through the water seal to ensure the normal operation of the equipment. When the abnormal low effective water level of the drainer caused by the pressure fluctuation of the gas pipe network or other reasons is broken down by the gas, under the action of the gas impact, the anti-leakage device is triggered to close the overflow port, prevent the gas from leaking out, and ensure the normal operation of the equipment. In general, when the height of the water seal is greater than 2000mm, the structure of two or three chambers should be used to keep the overflow water outlet below 2000mm, so as to facilitate the observation of the working condition of the drainer.


Precautions for installation and use

Electric heat trace leak proof gas drainer shall be installed on the flat ground, and shall be vertically installed and not tilted to ensure the reliable operation of the drainer.

The onsite gas pipe should be connected with the gas entry pipe of the gas drainer, and the flange should be connected with a gasket to ensure tight sealing and no gas leakage. The condensate drainpipe of the drainer must be connected to the nearby sewer. Do not directly discharge the condensate water to the base of the device.


Product Details


Electric heat trace leak proof gas drainer

email

aiteepcom@163.com

whatsapp

+ 0086-13015535452

Similar ProductsVIEW MORE >

  • Electric heat tracing gas drainer

    Electric heat tracing gas drainer

  • Steam heat trace leak proof gas drainer

    Steam heat trace leak proof gas drainer

  • Horizontal gas drainer

    Horizontal gas drainer

  • AT-CXLP-1600-200Y Leak proof gas drainer

    AT-CXLP-1600-200Y Leak proof gas drainer

  • Online message

    We will contact you within 24 hours

    GET GUIDANCE
    Copyright © Aite(Henan) environmental protection equipment Co.

    icon_online

    icon_email

    Contact Us

    icon_wehtapp Contact Us